Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch

Product Details
Customization: Available
Transport Package: Carton
Origin: Zhejiang, China
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
to see all verified strength labels (15)
  • Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
  • Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
  • Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
  • Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
  • Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
Find Similar Products

Basic Info.

Production Capacity
8000000pieces/Year

Product Description

Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch
 
Nxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off SwitchNxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off SwitchNxb Shunt Trip Unit Dz47s Mx+of Fire Forced Cut-off Switch

Accessory  Parameters
NXBDZ47S/TGB1N/DZ47 Series
1.Technical Parameters of Auxiliary Contacts and Alarm Contacts
Accessory Name Rated Current (A) AC:380V Rated Current (A)
AC:220V
Rated Current (A)
DC:110V
The number of contacts per group Purpose

auxiliary contact OF(iOP)
 
3 6 1

- Normally open - normally closed

 
Provide auxiliary signals and control auxiliary circuits

alarm contact SD(iSD)
 
3 6 1

- Normally open - normally closed

 
When the circuit breaker breaks due to a fault in the protected line, it provides an alarm signal

2.Technical Parameters of Shunt Release and Shunt Release + Auxiliary Contacts
 
Rated current (A) Rated current (A)

Tripping power consumption (W or VA)

 
pull-in voltage use
Shunt trip unit + auxiliary contact MX Active AC:110~380V
DC:110~220V
240 (0.7~1.1)
US
Remotely disconnect the circuit and control the auxiliary circuit through auxiliary contacts
AC/DC:24~48V 120
Passive AC:110~380V
DC:110~220V
240 (0.7~1.1)
US
AC/DC:24~48V 120
Shunt trip unit MX   AC:110~380V
DC:110~220V
240 US
(0.7~1.1)US
When the control voltage reaches 70% to 110% of the rated voltage, the circuit breaker trips reliably to achieve line protection
AC/DC:24~48V 120
 

3. Technical parameters of overvoltage, undervoltage, overundervoltage and undervoltage trip units

 

Attachment Name Rated control power supply
Voltage Ue
Trip voltage Function
Overvoltage trip unit
MV(iMSU)
AC230V Overvoltage value :270V±5% When the power supply voltage rises to 270V±5%, the circuit breaker is tripped to achieve overvoltage protection for the circuit.
Under-voltage trip unit
MN(iMN)
    AC230V Under-voltage value :<160V±5% When the power supply voltage drops below 160V, the circuit breaker is tripped to achieve undervoltage protection for the circuit.
Overvoltage and undervoltage trip unit MV+M
N(iMNV)
AC230V Overvoltage value :270V±5%
Under-voltage value :<160V±5%
When the power supply voltage rises to 270V±5% or drops below 160V, the circuit breaker is tripped to achieve line protection.
Three-phase overvoltage and undervoltage + phase loss MV+MN (iMNV) AC380V

Overvoltage value :460V±15V

Under-voltage value :300V±15V
 
When the power supply voltage rises to 460V±15V or drops below 300V±15V, the circuit breaker is tripped to achieve line protection.
Three-phase four-wire overvoltage and undervoltage MV+MN(iMNV) AC230V Overvoltage value :270V±5V Undervoltage value:<160V±5% When the power supply voltage rises to 270V±5V or drops below 160V±5V, the circuit breaker trips to achieve line protection.
Electronic undervoltage trip unit MNS (iMNS) AC230V Under-voltage value :170V±5%
Undervoltage value :0 tripping
When the power supply voltage drops to 170V±5% or there is no electricity, the circuit breaker trips to achieve undervoltage protection of the line (the circuit can be closed during power failure).
Electromagnetic undervoltage trip unit MNS (iMNS) AC230V Under-voltage value :35% to 75%
Undervoltage value :0 tripping
When the power supply voltage drops to 35% to 75% or there is no electricity, the circuit breaker trips to achieve undervoltage protection of the line (the circuit cannot be closed during a power outage).
Electromagnetic undervoltage trip unit MNS (iMNS)(For photovoltaic use) AC230V Under-voltage value :35% to 75%
Undervoltage value :0 trip (with delay)
When the power supply voltage drops to 35% to 75% or there is no electricity, the circuit breaker (delayed) trips to achieve undervoltage protection of the line (the circuit cannot be closed during power failure).
Electromagnetic overvoltage and undervoltage tripping
Instrument MNVS(iMNVS
(For photovoltaic use)
AC230V Overvoltage value :270V±5%
Under-voltage value :35% to 75%
Undervoltage value :0 trip (with delay)
When the power supply voltage rises to 270V±5V or drops to 35% - 75% or there is no electricity, the circuit breaker (delayed) trips to achieve overvoltage and undervoltage undervoltage protection of the line (the circuit cannot be closed during power failure).

 